General Specifications
Product Number 048FP4-T3101P20
Installation Methods Duct 
Cable type Loose tube
Environment Outdoor
Product type Dielectric
Fibre category SM NZ-DSF (G.655)
Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) A-DQ(ZN)2Y
Cable geometry Round
Standards
Fibre Standards ITU-T G.655 (all tables),  IEC 60793-2-50 Type B4,  TIA/EIA-492-EA00,  Telcordia GR-20 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Design And Test Criteria IEC 60794-3-10 
Waterblocking IEC 60794-1-2 F5
Environmental Conditions
Temperature range, installation -5 °C  to  50 °C    (23 °F  to  122 °F    )
Temperature range, operation -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Temperature range, storage -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Cable Design
Cable marking Metre - Handset - Sine - CORNING - Year - ALTOS (R) A-DQ(ZN)2Y 4X12 E10 LT 2.0
Central element GRP
Fibre count 48
Number of ripcords 2
Buffer tube colour coding, layer 1 Blue, orange, green, brown
Outer jacket colour Black
Outer jacket material High Density Polyethylene (HDPE)
Outer jacket nominal thickness 1.1 mm
Buffer tube diameter 2 mm
Central element diameter 2.1 mm
Number of active tubes 4
Number of filling elements 2
Number of tube positions 6
Fibre colouring Blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, turquoise
Fibres per tube 12 
Colour Code Standards Telcordia
Buffer Tube Colour Coding, Layer 2 Blue, orange, green, brown
Mechanical Specifications
Crush resistance 1500 N/10 cm
Max. tensile strength for installation 1500 N
Min. bend radius installation 166 mm
Min. bend radius operation 83 mm
Nominal outer diameter 8.3 mm 
Optical Characteristics
Fibre code F
Performance option code 01
Fibre category OS2 
Fibre Type Single-mode (OS2) / 250 µm
Fibre name LEAF®
Maximum Attenuation - / - / 0.25 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fibre compliance ITU-T G.655.D
Dimensions
Cable Weight 54 kg/km
Max. cable length per reel/drum 6000 m
All-dielectric cable construction
Requires no grounding or bonding
UV- and microbe-resistant
Can be installed in ducts or conduits
Waterblocking technology
OSP (outdoor) applications
Fibres/buffer tubes colour coded to Telcordia-Bellcore
Easy identification of the individual tubes and fibres
Dry cable core by means of water swellable elements