012ZK4-13120ADE
MiniXtend® Cable, CT A-D(ZN)2Y, 12 F, CT, Single-mode (SMF 28e® ULTRA) - VDE
General Specifications
Product Number | 012ZK4-13120ADE |
Cable Type | Single Tube |
Environment | Outdoor |
Product Type | Dielectric |
Fiber Category | Single-mode (OS2) |
Application | Miniduct |
Cable geometry | Round |
Standards
Fiber Standards | TIA/EIA-492CAAB, IEC 60793-2-50 Type B1.3, ITU-T G.652.D and ITU-T G.657.A1, ISO/IEC 11801 Ed.2.2 |
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Environmental Conditions
Temperature Range, Installation | -5 °C to 50 °C (23 °F to 122 °F ) |
Temperature Range, Operation | -20 °C to 60 °C (-4 °F to 140 °F ) |
Temperature Range, Storage | -25 °C to 60 °C (-13 °F to 140 °F ) |
Cable Design
Cable Marking | Meter Handset D-Sine CORNING Year MINIXTEND(R) A-D(ZN)2Y 12F E9U CT1.7 |
Fiber Count | 12 |
Outer Jacket Color | Black |
Outer Jacket Material | Polyethylene (PE) |
Buffer Tube Diameter | 1.75 mm (0.07 in) |
Cable Marking Method | Laser printing |
Cable Marking Color | White |
Fiber Coloring | Red, Green, Blue, Yellow, White, Slate, Brown, Violet, Aqua, Black, Orange, Rose |
Fibers per Tube | 12 |
Mechanical Specifications
Crush Resistance | 1000 N/10 cm |
Max. Tensile Strength, Short-Term | 80 N (17.98 lbf) |
Min. Bend Radius Installation | 20 mm (0.79 in) |
Nominal Outer Diameter | 2.5 mm (0.1 in ) |
Optische Eigenschaften
Fasercode | Z |
Leistungsklassen-Code | 20 |
Faserkategorie | OS2 |
Fasertyp | Single-mode (OS2) / 250 µm |
Fasername | Singlemode (OS2), biegeoptimiert |
Maximale Dämpfung | 0,34 dB/km / 0,34 dB/km / 0,20 dB/km |
Wellenlänge | 1310 nm / 1383 nm / 1550 nm |
Faserkonformität | ITU-T G.652.D und ITU-T G.657.A1 |
Faserkerndurchmesser | 8,2 µm |
Mantelglasdurchmesser | 125 µm |
Coating-Durchmesser | 242 µm |
Dispersion bei 1550 nm | ≤ 18 [ps/(nm*km)] |
Dispersion bei 1625 nm | ≤ 22 [ps/(nm*km)] |
Kabel-Grenzwellenlänge | 1260 nm |
Modenfelddurchmesser bei 1310 nm | 9,2 µm |
Modenfelddurchmesser bei 1550 nm | 10,4 µm |
PMD (Polarisationsmodendispersion) Link Design Wert | ≤ 0,04 ps/√km |
Maximale Polarisationsmodendispersion (PMD) der einzelnen Faser | ≤ 0,1 ps/√km |
Dimensions
Cable Weight | 4.5 kg/km (3.02 lb/1000 ft) |
Max. cable length per reel/drum | 6000 m (19680 ft) |
Bessere Kabel- und Faserdichte
Reduzierter Kabeldurchmesser für Installation in Mikrorohrsystemen mit mindestens 4 mm Innendurchmesser
Nicht metallischer Kabelaufbau
Keine Erdung erforderlich
Optimiert für die luftunterstützte Verlegung in Mikrorohrsystemen
Verlegungsentfernungen über 1500m/min mit Geschwindigkeiten bis 70m/min
SMF-28e+® entsprechend ITU-T G.652.D
Sichere Übertragungseigenschaften und niedrige Dämpfung