text.skipToContent text.skipToNavigation

002EK4-13122A20

MiniXtend® Cable, CT  A-D(ZN)2Y, 1x2 F, CT, Single-mode (SMF 28e+®)

Contact Distributor for Lead Time
General Specifications
Product Number 002EK4-13122A20
Installation Methods Microduct 
Cable Type Single Tube
Environment Outdoor
Product Type Dielectric
Fiber Category Single-mode (OS2)
Cable geometry Round
Standards
Fiber Standards TIA/EIA-492CAAB,  IEC 60793-2-50 Type B1.3,  ITU-T G.652.D,  ISO/IEC 11801 Ed.2.2 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Installation -5 °C  to  50 °C    (23 °F  to  122 °F    )
Temperature Range, Operation -20 °C  to  60 °C    (-4 °F  to  140 °F    )
Temperature Range, Storage -25 °C  to  60 °C    (-13 °F  to  140 °F    )
Cable Design
Cable Marking Meter Handset D-Sine CORNING Year MINIXTEND(R) A-D(ZN)2Y 2F E9 CT1.7
Fiber Count 2
Number of Ripcords 1
Outer Jacket Color Black
Outer Jacket Material Polyethylene (PE)
Buffer Tube Diameter 1.75 mm
Cable Marking Method Laser printing
Cable Marking Color White
Fiber Coloring Blue, Orange
Fibers per Tube 2 
Mechanical Specifications
Crush Resistance 1000 N/10 cm
Crush Resistance (reversible), Outdoor Cable 500 N/10 cm
Max. Tensile Strength, Short-Term 80 N
Min. Bend Radius Installation 90 mm
Min. Bend Radius Operation 50 mm
Nominal Outer Diameter 2.5 mm 
Min. Duct Size Diameter 3.5 mm
Optimal Duct Size 4 mm
Optical Characteristics
Fiber Code E
Performance Option Code 22
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name Single-mode (OS2)
Maximum Attenuation 0.36 dB/km / 0.36 dB/km / 0.22 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Compliance ITU-T G.652.D
Fiber Core Diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm*km)]
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 9.2 µm
Mode-Field Diameter at 1550 nm 10.4 µm
PMD Link Design Value ≤ 0.06 ps/√km
PMD maximum individual fiber ≤ 0.1 ps/√km
Dimensions
Cable Weight 4.9 kg/km
Max. cable length per reel/drum 6000 m
Improved cable and fiber density
Reduced cable diameter for installation in micro ducts with 4mm minimum inner diameter
Fully dielectric
No grounding required
Optimized for air-assisted install in microducts
Capable of installation distances greater than 2000 m (6560 ft) at speeds up to 150 m/min (490 ft/min)
SMF-28e+®according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion