text.skipToContent text.skipToNavigation

D1D101JB49R010M

Evolv® ROC™ Drop Assembly  Pushlok® dielectric, 10 m, bulk packaging

Trouvez votre distributeur Délais de livraison à reception de la commande
Spécifications générales
Référence du produit D1D101JB49R010M
Fiber Category ClearCurve® LBL
Cable Assembly Type Drop Assemblies
Environment Outdoor
Application FTTH 
Number of Pulling Grips 0
Cable Type ROC™ dielectric drop
Connector Assembly Type Pushlok to Pushlok
Packaging Bulk Pack
Preconnectorized "Stubbed" Hardware Yes
Solution Evolv®
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Design
Fiber Count 1
Outer Jacket Color Black
Fiber Type Single-mode
Mechanical Specifications
Cold Mate/Demate -40 °C (-40 °F)
Axial Pull, Plug to Cable, Through the Dust Cap 444.82 N (100 lb) in axial pull with load applied to the dust cap
Optical Characteristics
Fiber Code J
Performance Option Code 22
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name ClearCurve® LBL
Maximum Attenuation 0.36 dB/km / 0.36 dB/km / 0.22 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Compliance ITU-T G.652.D and ITU-T G.657.A2/B2
Fiber Core Diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 23 [ps/(nm*km)]
Fiber Bend Performance at 1550nm 7.5mm radius ≤ 0.4 dB/turn
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 8.6 µm
Mode-Field Diameter at 1550 nm 9.6 µm
PMD Link Design Value ≤ 0.06 ps/√km
PMD maximum individual fiber ≤ 0.2 ps/√km
Parallel Optics 40 Gigabit Ethernet 150 m / -
Specifications - Connector A
Insertion Loss, Typical ≤ 0.15 dB
Insertion Loss, Max. 0.3 dB
Connector Type Pushlok
Ferrule Material Zirconia
Specifications - Connector B
Reflectance, Typical > 65 dB
Insertion Loss, Typical ≤ 0.15 dB
Insertion Loss, Max. 0.3 dB
Connector Type Pushlok
Ferrule Material Zirconia
Dimensions
Length 10 m
Ordering Information
Packaging Method Bulk Pack
Connectique renforcée
Connecteur Pushlok au diamètre miniaturisé
Smaller profile and bend radius, flexibility allows for increased slack storage capacity in existing optical network terminals (ONTs), pedestals and handholes
 
Design renforcé
Large choix de connectique
hybrid assemblies with hardened connector (terminal) to SC APC (ONT)
Offre pour tous les types d&rsquo
Aerial: dielectric, self-supporting at 40 lbs installation tension at 150 ft (NESC Heavy), 255 ft (NESC Medium) or 330 ft (NESC Light)Direct-buried: toneable for easy locatingDuct: integral pulling eye/connector cap designed for 100 lb maximum pulling tension