S46998-A2-A46
UCNCP Closures 9-20 in-line closure, E-type
Standards
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Design
| Splitter support | No |
| Buffer Storage | Installed |
| Bulletproof housing | No |
| Central member fixing for main cable | Yes |
| Closure Shape | In-Line |
| Colored trays | No |
| Crimp splice count per tray | 24 |
| Crimp splice protector support | Yes |
| Customer logo on housing | On demand |
| Distribution cable port count | 12 |
| Distribution cable range | 12 mm to 25 mm |
| Grounding system | Metric |
| Heat shrink splice count per tray | 12 |
| Heat shrink splice protector support | Yes |
| Main cable circular port count | 2 |
| Main cable oval port count | 0 |
| Max number of trays | 24 Standard |
| Maximum splice fiber capacity | 288 splices |
| Maximum tray count | 24 |
| Number of Distribution/Drop Cables ports | 12 |
| Sealing Type | Mechanical |
| Size by Fiber Splice Capacity | 288 |
| Splice Tray Type | Standard |
| SplicePak splice count per tray | 0 |
| SplicePak splice protector support | No |
| Supported cables | Figure-8 Drop Cable |
| System | STD |
| Trays pre-installed | On demand |
| Water sensor tray | No |
| Working environment | Manhole / Underground |
Ordering Information
| Units per Delivery | 1/1 |
| Shipping Width | 780 mm |
| Shipping Depth | 230 mm |