text.skipToContent text.skipToNavigation

006ZK4-13122A20

MiniXtend® Cable, CT  A-D(ZN)2Y, 6 F, CT, Single-mode (E9 G.657.A1)

Trouvez votre distributeur Délais de livraison à reception de la commande
Spécifications générales
Référence du produit 006ZK4-13122A20
Installation Methods Microduct 
Cable Type Single Tube
Environment Outdoor
Product Type Dielectric
Fiber Category SMF-28® Ultra
Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) A-D(ZN)2Y
Cable geometry Round
Standards
Fiber Standards TIA/EIA-492CAAB,  IEC 60793-2-50 Type B1.3,  ITU-T G.652.D and ITU-T G.657.A1,  ISO/IEC 11801 Ed.2.2 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Installation -5 °C  -  50 °C    (23 °F  -  122 °F    )
Temperature Range, Operation -20 °C  -  60 °C    (-4 °F  -  140 °F    )
Temperature Range, Storage -25 °C  -  60 °C    (-13 °F  -  140 °F    )
Cable Design
Fiber Count 6
Outer Jacket Color Black
Outer Jacket Material Polyethylene (PE)
Buffer Tube Diameter 1.75 mm
Cable Marking Method Laser printing
Fiber Coloring Blue, Orange, Green, Brown, Slate, White
Fibers per Tube
Mechanical Specifications
Crush Resistance 1000 N/10 cm
Crush Resistance (reversible), Outdoor Cable 500 N/10 cm
Max. Tensile Strength, Short-Term 80 N
Min. Bend Radius Installation 90 mm
Min. Bend Radius Operation 50 mm
Nominal Outer Diameter 2.5 mm 
Min. Duct Size Diameter 3.5 mm
Optimal Duct Size 4 mm
Dimensions
Cable Weight 4.5 kg/km
Max. cable length per reel/drum 6000 m
Amélioration de la densité des câbles et des fibres
Diamètre de câble réduit pour l'installation dans des systèmes de microtubes d'un diamètre intérieur d'au moins 4 mm
Diélectrique
Pas de mise à la terre requise
Optimisé pour installation par soufflage dans des micro-conduites
Distances d'installation: plus de 2000 m (6560 ft) à une vitesse de 150 m/min (490 ft/min)
SMF-28e+® conforme à la norme ITU-T G.652.D
Propriétés de transmission sûres et faible atténuation