006ZK4-13122A20
MiniXtend® Cable, CT A-D(ZN)2Y, 6 F, CT, Single-mode (E9 G.657.A1)
General Specifications
| Product Number | 006ZK4-13122A20 |
| Cable Type | Single Tube |
| Environment | Outdoor |
| Product Type | Dielectric |
| Fiber Category | SMF-28® Ultra |
| Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) | A-D(ZN)2Y |
| Application | Microduct |
| Cable geometry | Round |
Standards
| Fiber Standards | TIA/EIA-492CAAB, IEC 60793-2-50 Type B1.3, ITU-T G.652.D and ITU-T G.657.A1, ISO/IEC 11801 Ed.2.2 |
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Environmental Conditions
| Temperature Range, Installation | -5 °C to 50 °C (23 °F to 122 °F ) |
| Temperature Range, Operation | -20 °C to 60 °C (-4 °F to 140 °F ) |
| Temperature Range, Storage | -25 °C to 60 °C (-13 °F to 140 °F ) |
Cable Design
| Fiber Count | 6 |
| Outer Jacket Color | Black |
| Outer Jacket Material | Polyethylene (PE) |
| Buffer Tube Diameter | 1.75 mm |
| Cable Marking Method | Laser printing |
| Fiber Coloring | Blue, Orange, Green, Brown, Slate, White |
| Fibers per Tube | 6 |
Mechanical Specifications
| Crush Resistance | 1000 N/10 cm |
| Crush Resistance (reversible), Outdoor Cable | 500 N/10 cm |
| Max. Tensile Strength, Short-Term | 80 N |
| Min. Bend Radius Installation | 90 mm |
| Min. Bend Radius Operation | 50 mm |
| Nominal Outer Diameter | 2.5 mm |
| Min. Duct Size Diameter | 3.5 mm |
| Optimal Duct Size | 4 mm |
Dimensions
| Cable Weight | 4.5 kg/km |
| Max. cable length per reel/drum | 6000 m |
Improved cable and fiber density
Reduced cable diameter for installation in micro ducts with 4mm minimum inner diameter
Fully dielectric
No grounding required
Optimized for air-assisted install in microducts
Capable of installation distances greater than 2000 m (6560 ft) at speeds up to 150 m/min (490 ft/min)
SMF-28e+®according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion