text.skipToContent text.skipToNavigation

096FR4-T3101A20

ALTOS® Loose Tube Outdoor Duct Cable LT 2.3  8x12 E10 LEAF® ITU G655

Contact Distributor for Lead Time

General Specifications
Product Number 096FR4-T3101A20
Cable type Loose tube
Environment Outdoor
Product type Dielectric
Fibre category SM NZ-DSF (G.655)
Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) A-DQ(ZN)2Y
Application Duct 
Cable geometry Round
Standards
Fibre Standards ITU-T G.655 (all tables),  IEC 60793-2-50 Type B4,  TIA/EIA-492-EA00,  Telcordia GR-20 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Waterblocking IEC 60794-1-2 F5
Environmental Conditions
Temperature range, installation -5 °C  to  50 °C   
Temperature range, operation -30 °C  to  70 °C   
Temperature range, storage -40 °C  to  70 °C   
Cable Design
Cable marking Metre - Handset - Sine - CORNING - Year -ALTOS (R) A-DQ(ZN)2Y 8X12 E10 LT 2.3
Central element Dielectric with Polyethylene coating
Fibre count 96
Number of ripcords 1
Outer jacket colour Black
Outer jacket material Linear Low Density Polyethylene (LLDPE)
Outer jacket nominal thickness 1.5 mm
Buffer tube colour Blue, orange, green, brown, grey, white, red, black
Buffer tube diameter 2.25 mm
Central element diameter 3.9 mm
Number of active tubes 8
Number of tube positions 8
Tape Water-swellable
Fibre colouring Blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, turquoise
Fibres per tube 12 
Colour Code Standards Telcordia
Mechanical Specifications
Crush resistance 2000 N/10 cm
Max. tensile strength for installation 2700 N
Min. bend radius installation 210 mm
Min. bend radius operation 180 mm
Nominal outer diameter 11.9 mm 
Optical Characteristics
Fibre code F
Performance option code 01
Fibre category OS2 
Fibre Type Single-mode (OS2) / 250 µm
Fibre name LEAF®
Maximum Attenuation - / - / 0.25 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fibre compliance ITU-T G.655.D
Dimensions
Cable Weight 113 kg/km
Max. cable length per reel/drum 6000 m
All-dielectric cable construction
Requires no grounding or bonding
UV- and microbe-resistant
Can be installed in ducts or conduits
Waterblocking technology
OSP (outdoor) applications
Fibres/buffer tubes colour coded to Telcordia-Bellcore
Easy identification of the individual tubes and fibres
Dry cable core by means of water swellable elements
Allows efficient and craft-friendly cable preparation in outdoor applications