004Z8Z-32125E2G
MIC™ Tight Buffer Indoor Cable 4F E9/125 SMF-28® ULTRA 0.9 mm TB3, Dca-s1a, d1, a1
General Specifications
| Product Number | 004Z8Z-32125E2G |
| Installation Methods | Horizontal, Riser |
| Cable type | Tight-buffered |
| Environment | Indoor |
| Product type | Dielectric |
| Fibre category | SMF-28® Ultra |
| Flame rating | LSZH/FRNC |
| Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) | J-V(ZN)H |
| Cable geometry | Round |
Standards
| Reaction to Fire | Dca, s1a, d1, a1 |
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
| Flame propagation test | Flame retardant according to IEC 60332-1-2 (single cable) and IEC 60332-3-24 (bunch of cables) |
| Reaction to Fire Requirements | Reaction to fire according to EN 50575 and EN 13501-6 |
| Smoke density | Low Smoke to IEC 61034 |
| Halogen content test | Zero Halogen according to IEC 60754-1 |
| Level of corrosion | Non-corrosive according to IEC 60754-2 |
Environmental Conditions
| Temperature range, installation | -5 °C to 50 °C |
| Temperature range, operation | -20 °C to 60 °C |
| Temperature range, storage | -25 °C to 70 °C |
Cable Design
| Cable marking | Metre - Handset - Sine - CORNING - Fibre Optic Cable - Year - MIC(R) J-V(ZN)H 4 E9ULTRA/125 TB3 0.9 LSZH(TM)/FRNC |
| Central element | Yarn |
| Fibre count | 4 |
| Number of ripcords | 1 |
| Outer jacket colour | Ivory |
| Buffering diameter | 900 µm |
| Outer jacket material | Flame-retardant, non-corrosive/low-smoke, silicon-free, zero-halogen (FRNC/LSZH) material |
| Outer jacket nominal thickness | 0.8 mm |
| Tensile strength elements and/or armouring - Layer 1 | Aramid yarn |
| Tensile strength elements and/or armouring | Aramid yarn |
| Tight buffer colour | Blue, orange, green, brown |
| Tight buffer type | TB3 (easy strip up to 10 cm) |
| Cable marking method | Inkjet printing |
| Flame rating | LSZH/FRNC |
Mechanical Specifications
| Crush resistance | 1000 N/10 cm |
| Crush resistance (reversible), outdoor cable | 1000 N/10 cm |
| Fire load | 0.35 MJ/m |
| Max. tensile strength for installation | 600 N |
| Min. bend radius installation | 63 mm |
| Min. bend radius operation | 42 mm |
| Nominal outer diameter | 4.2 mm |
Optical Characteristics
| Fibre code | Z |
| Performance option code | 25 |
| Fibre category | OS2 |
| Fibre Type | Single-mode (OS2) / 250 µm |
| Fibre name | Bend-Improved Single-mode (OS2) |
| Maximum Attenuation | 0.38 dB/km / 0.38 dB/km / 0.25 dB/km |
| Wavelengths | 1310 nm / 1383 nm / 1550 nm |
| Fibre compliance | ITU-T G.652.D and ITU-T G.657.A1 |
| Fibre core diameter | 8.2 µm |
| Cladding diameter | 125 µm |
| Coating diameter | 242 µm |
| Dispersion @ 1550 nm | ≤ 18 [ps/(nm*km)] |
| Dispersion @ 1625 nm | ≤ 22 [ps/(nm*km)] |
| Cable cutoff wavelength | 1260 nm |
| Mode-Field Diameter at 1310 nm | 9.2 µm |
| Mode-Field Diameter at 1550 nm | 10.4 µm |
| PMD Link Design Value | ≤ 0.04 ps/√km |
| PMD (Polarization Mode Dispersion) maximum individual fibre | ≤ 0.1 ps/√km |
Dimensions
| Cable Weight | 18 kg/km |
| Max. cable length per reel/drum | 4000 m |
All-dielectric cable construction
Requires no grounding or bonding
Small diameter and bend radius
Easy installation in space-constrained areas
TB3 tight-buffered construction
Easy and consistent stripping over 10 cm
Silicon-free outer jacket
The cable jacket and the outer jacket of subunits (not valid for 900 µm tight buffers) are free of harmful components to paint structures
Flame retardant
LSZH™/FRNC