D1D101JB49R010M
Evolv® ROC™ Drop Assembly Pushlok® dielectric, 10 m, bulk packaging
Spécifications générales
Référence du produit | D1D101JB49R010M |
Fibre category | ClearCurve® LBL |
Cable assembly type | Drop Assemblies |
Environment | Outdoor |
Application | Fiber to the Premises (FTTP) |
Number of pulling grips | 0 |
Cable Type | ROC™ dielectric drop |
Connector Assembly Type | Pushlok to Pushlok |
Packaging | Bulk Pack |
Solution | Evolv® |
Standards
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Design
Fibre count | 1 |
Outer jacket colour | Black |
Fibre Type | Single-mode |
Mechanical Characteristics
Cold mate/demate | -40 °C |
Axial pull, plug to cable, through the dust cap | 444.82 N (100 lb) in axial pull with load applied to the dust cap |
Optical Characteristics
Fibre code | J |
Performance option code | 22 |
Fibre category | OS2 |
Fibre Type | Single-mode (OS2) / 250 µm |
Fibre name | ClearCurve® LBL |
Maximum Attenuation | 0.36 dB/km / 0.36 dB/km / 0.22 dB/km |
Wavelengths | 1310 nm / 1383 nm / 1550 nm |
Fibre compliance | ITU-T G.652.D and ITU-T G.657.A2/B2 |
Fibre core diameter | 8.2 µm |
Cladding diameter | 125 µm |
Coating diameter | 242 µm |
Dispersion @ 1550 nm | ≤ 18 [ps/(nm*km)] |
Dispersion @ 1625 nm | ≤ 23 [ps/(nm*km)] |
Fibre Bend Performance at 1550nm 7.5mm radius | ≤ 0.4 dB/turn |
Cable cutoff wavelength | 1260 nm |
Mode-Field Diameter at 1310 nm | 8.6 µm |
Mode-Field Diameter at 1550 nm | 9.6 µm |
PMD Link Design Value | ≤ 0.06 ps/√km |
PMD (Polarization Mode Dispersion) maximum individual fibre | ≤ 0.2 ps/√km |
Parallel optics 40 gigabit ethernet | 150 m / - |
Specifications - Connector A
Reflectance, typical | > 65 dB |
Insertion loss, typical | ≤ 0.15 dB |
Insertion loss, max. | 0.3 dB |
Connector type | Pushlok |
Ferrule material | Zirconia |
Specifications - Connector B
Reflectance, typical | > 65 dB |
Insertion loss, typical | ≤ 0.15 dB |
Insertion loss, max. | 0.3 dB |
Connector type | Pushlok |
Ferrule material | Zirconia |
Dimensions
Length | 10 m |
Ordering Information
Packaging method | Bulk Pack |
Connectique renforcée
Connecteur Pushlok® au diamètre miniaturisé
Coupe transversale optimisée réduite du câble
Smaller profile and bend radius, flexibility allows for increased slack storage capacity in existing optical network terminals (ONTs), pedestals and handholes
Design robuste
Conçu pour une connexion rapide à des adaptateurs de cloison encastrés externes sur des bornes ou des boitiers
Large choix de connectique
hybrid assemblies with hardened connector (terminal) to SC APC (ONT)
Environnements d'installation polyvalents
Aerial: dielectric, self-supporting at 40 lbs installation tension at 150 ft (NESC Heavy), 255 ft (NESC Medium) or 330 ft (NESC Light)Direct-buried: toneable for easy locatingDuct: integral pulling eye/connector cap designed for 100 lb maximum pulling tension