MiniXtend® Cable, LT, A-DQ(ZN)2Y 8x12 E9/125 (OS2)
通用规范
| 产品编码 | 096EM4-T3122A20 |
| Cable type | Stranded Loose Tube |
| Environment | Outdoor |
| Product type | Dielectric |
| Fibre category | Single-mode (OS2) |
| Application | Microduct |
| Cable geometry | Round |
Standards
| Fibre Standards | TIA/EIA-492CAAB, IEC 60793-2-50 Type B1.3, ITU-T G.652.D, ISO/IEC 11801 Ed.2.2 Cat. OS2, IEC 60794-3:2001, Section 5.5, Method 1 (m=20, Q=0.01%) |
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Environmental Conditions
| Temperature range, installation | -5 °C - 40 °C |
| Temperature range, operation | -30 °C - 70 °C |
| Temperature range, storage | -30 °C - 70 °C |
Cable Design
| Cable marking | Metre - Handset - Sine - CORNING - Year -MINIXTEND (R) CABLE 8X12 E9/125 LT 1.4 |
| Central element | Dielectric |
| Fibre count | 96 |
| Number of ripcords | 2 |
| Outer jacket colour | Black |
| Outer jacket material | High Density Polyethylene (HDPE) |
| Outer jacket nominal thickness | 0.5 mm |
| Buffer tube diameter | 1.4 mm |
| Number of active tubes | 8 |
| Number of tube positions | 8 |
| Tape | Water-swellable |
| Fibre colouring | Blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, turquoise |
| Fibres per tube | 12 |
Mechanical Specifications
| Crush resistance | 1000 N/10 cm |
| Max. tensile strength, short-term | 1000 N |
| Min. bend radius installation | 126 mm |
| Min. bend radius operation | 94.5 mm |
| Nominal outer diameter | 6.3 mm |
光学特性
| 光纤代码 | E |
| 性能选项代码 | 22 |
| 光纤类别 | OS2 |
| 光纤类型 | Single-mode (OS2) / 250 µm |
| 光纤名称 | 单模(OS2) |
| 最大衰减 | 0.36 dB/km / 0.36 dB/km / 0.22 dB/km |
| 波长 | 1310 nm / 1383 nm / 1550 nm |
| 光纤符合性 | ITU-T G.652.D |
| 光纤纤芯直径 | 8.2 µm |
| 包层直径 | 125 µm |
| 涂层直径 | 242 µm |
| Dispersion @ 1550 nm | ≤ 18 [ps/(nm*km)] |
| Dispersion @ 1625 nm | ≤ 22 [ps/(nm*km)] |
| 光缆截止波长 | 1260 nm |
| 在1310nm的模场直径 | 9.2 µm |
| 1550nm的模场直径 | 10.4 µm |
| PMD链路设计值 | ≤ 0.06 ps/√km |
| PMD最大单独光纤 | ≤ 0.1 ps/√km |
Dimensions
| Cable Weight | 35 kg/km |
| Max. cable length per reel/drum | 4000 m |
Reduced outer cable diameter
High fiber density in microduct systems
Compact and light
CapEx-optimized installations and upgrades
Optimized cable stiffness
Long installation lengths
Fully dielectric
No grounding required
Color-coded tubes and fibers
Easy identification of tubes and fibers
SMF-28e+® according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion