text.skipToContent text.skipToNavigation

008ZB4-13120A20

SST-Drop™ Single-Tube, Dielectric, Gel-Filled Cable  8 F, E9/125 SMF-28® ULTRA

Contact Distributor for Lead Time

General Specifications
Product Number 008ZB4-13120A20
Cable type Central Tube
Environment Outdoor
Product type Self-Supporting, Figure-8
Fibre category SMF-28® Ultra fibre
Application Aerial,  Duct,  Drop 
Cable geometry Other
Standards
Reaction to fire Fca
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Waterblocking IEC 60794-1-22 Method F5B
Level of corrosion Non-corrosive according to IEC 60754-2
Environmental Conditions
Temperature range, installation -30 °C  to  70 °C   
Temperature range, operation -40 °C  to  70 °C   
Temperature range, storage -40 °C  to  70 °C   
Cable Design
Cable marking Metre - CORNING -Month/Year - Handset - 8E9ULTRA - ID Number
Central element Dielectric
Fibre count 8
Outer jacket colour Black
Outer jacket material Polyethylene (PE)
Buffer tube diameter 3 mm
Cable marking colour White
Fibre colouring Blue, orange, green, brown, grey, white, red, black
Fibres per tube
Colour Code Standards Telcordia
Mechanical Specifications
Crush resistance 3000 N/10 cm
Max. tensile strength, long-term 400 N
Max. tensile strength, short-term 1350 N
Min. bend radius operation 80 mm
Nominal outer diameter 8.1 mm x  4.5 mm 
Optical Characteristics
Cable cutoff wavelength 1260 nm
Fibre code Z
Fibre name SMF-28® Ultra fibre
Fibre Type Single-mode
Fibre compliance ITU-T G.652.D and ITU-T G.657.A1
Fibre core diameter 8.2 µm
Cladding diameter 125 µm
Maximum Attenuation 0.34 dB/km / 0.34 dB/km / 0.20 dB/km
Mode-Field Diameter at 1310 nm 9.2 µm
Typical attenuation 0.32 dB/km / 0.32 dB/km / 0.18 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
PMD Link Design Value ≤ 0.04 ps/(nm*km)
PMD (Polarization Mode Dispersion) maximum individual fibre ≤ 0.1 ps/(nm*km)
Coating diameter 242 µm
Fibre category OS2 
Dispersion @ 1550 nm ≤ 18 [ps/(nm ⋅ km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm ⋅ km)]
Dimensions
Cable Weight 30 kg/km
Length 0 mm
Dielectric design
Eliminates bonding
Standard ALTOS Cable tube design in single tube design
Standard practices and hardware compatibility
Crush Resistance
Fibre protection and signal integrity