text.skipToContent text.skipToNavigation

00D101JB49R085M

Evolv® ROC™ Drop Assembly  Pushlok® Pigtail, dielectric, 85 m, bulk packaging

Contact Distributor for Lead Time

General Specifications
Product Number 00D101JB49R085M
Fibre category ClearCurve® LBL
Cable assembly type Drop Assemblies
Environment Outdoor
Application FTTH 
Number of pulling grips 0
Cable Type ROC™ dielectric drop
Connector Assembly Type Pigtail to Pushlok
Packaging Bulk Pack
Preconnectorized "Stubbed" hardware Yes
Solution Evolv®
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Design
Fibre count 1
Outer jacket colour Black
Fibre Type Single-mode
Mechanical Characteristics
Cold mate/demate -40 °C
Axial pull, plug to cable, through the dust cap 444.82 N (100 lb) in axial pull with load applied to the dust cap
Optical Characteristics
Fibre code J
Performance option code 22
Fibre category OS2 
Fibre Type Single-mode (OS2) / 250 µm
Fibre name ClearCurve® LBL
Maximum Attenuation 0.36 dB/km / 0.36 dB/km / 0.22 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fibre compliance ITU-T G.652.D and ITU-T G.657.A2/B2
Fibre core diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 23 [ps/(nm*km)]
Fibre Bend Performance at 1550nm 7.5mm radius ≤ 0.4 dB/turn
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 8.6 µm
Mode-Field Diameter at 1550 nm 9.6 µm
PMD Link Design Value ≤ 0.06 ps/√km
PMD (Polarization Mode Dispersion) maximum individual fibre ≤ 0.2 ps/√km
Parallel optics 40 gigabit ethernet 150 m / -
Specifications - Connector A
Insertion loss, typical ≤ 0.15 dB
Connector type Pigtail
Specifications - Connector B
Reflectance, typical > 65 dB
Insertion loss, typical ≤ 0.15 dB
Insertion loss, max. 0.3 dB
Connector type Pushlok®
Ferrule material Zirconia
Dimensions
Length 85 m
Ordering Information
Packaging method Bulk Pack
Hardened connector technology
Reduced diameter Pushlok™ connector
Reduced optimised cable cross section
Smaller profile and bend radius; flexibility allows for increased slack storage capacity in existing optical network terminals (ONTs), pedestals, and handholes
Robust design
Designed for rapid connection to external flush-mounted bulkhead adapters on terminals or closures
Flexible connector offerings
Dual-ended or pigtailed versions to accommodate any ONT interface; hybrid assemblies with hardened connector (terminal) to SC APC (ONT)
Versatile installation environments
Aerial: dielectric, self-supporting at 40 lbs installation tension at 150 ft (NESC Heavy), 255 ft (NESC Medium) or 330 ft (NESC Light)
Direct-buried: toneable for easy locating
Duct: integral pulling eye/connector cap designed for 100 lb maximum pulling tension; Pushlok connector is suitable for 13 mm inner diameter duct