text.skipToContent text.skipToNavigation

004ZK4-13120A20

MiniXtend® Cable, CT  A-D(ZN)2Y, 4 fibres, CT, single-mode (SMF 28e® ULTRA)

Contact Distributor for Lead Time

General Specifications
Product Number 004ZK4-13120A20
Cable type Central Tube
Environment Outdoor
Product type Dielectric
Fibre category Single-mode (OS2)
Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) A-D(ZN)2Y
Application Microduct 
Cable geometry Round
Standards
Fibre Standards TIA/EIA-492CAAB,  IEC 60793-2-50 Type B1.3,  ITU-T G.652.D and ITU-T G.657.A1,  ISO/IEC 11801 Ed.2.2 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature range, installation -5 °C  to  50 °C   
Temperature range, operation -20 °C  to  60 °C   
Temperature range, storage -25 °C  to  60 °C   
Cable Design
Cable marking Metre Handset D-Sine CORNING Year MINIXTEND(R) A-D(ZN)2Y 4F E9U CT1.7
Fibre count 4
Outer jacket colour Black
Outer jacket material Polyethylene (PE)
Buffer tube diameter 1.75 mm
Cable marking method Laser printing
Cable marking colour White
Fibre colouring Blue, orange, green, brown
Fibres per tube
Mechanical Specifications
Crush resistance 1000 N/10 cm
Crush resistance (reversible), outdoor cable 500 N/10 cm
Max. tensile strength, short-term 80 N
Min. bend radius installation 90 mm
Min. bend radius operation 50 mm
Nominal outer diameter 2.5 mm 
Min. Duct Size Diameter 3.5 mm
Optimal Duct Size 4 mm
Características ópticas
Código da fibra Z
Código de opção de desempenho 20
Categoria da fibra OS2 
Tipo de fibra Single-mode (OS2) / 250 µm
Nome da fibra Monomodo de curvatura aprimorada (OS2)
Atenuação máxima 0.34 dB/km / 0.34 dB/km / 0.20 dB/km
Comprimentos de onda 1310 nm / 1383 nm / 1550 nm
Conformidade de fibra ITU-T G.652.D e ITU-T G.657.A1
Diâmetro do núcleo da fibra 8,2 µm
Diâmetro da casca 125 µm
Diâmetro do revestimento 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm*km)]
Comprimento de onda de corte do cabo 1260 nm
Diâmetro do campo modal em 1310 nm 9,2 µm
Diâmetro do campo modal em 1550 nm 10,4 µm
Valor de projeto do link PMD ≤ 0,04 ps/√km
PMD máximo Fibra individual ≤ 0,1 ps/√km
Dimensions
Cable Weight 4.5 kg/km
Max. cable length per reel/drum 6000 m
Improved cable and fiber density
Reduced cable diameter for installation in micro ducts with 4mm minimum inner diameter
Fully dielectric
No grounding required
Optimized for air-assisted install in microducts
Capable of installation distances greater than 2000 m (6560 ft) at speeds up to 150 m/min (490 ft/min)
SMF-28e+®according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion