036ZK4-13142A20
MiniXtend® Cable, CT A-D(ZN)2Y,36 fibres, CT, single-mode (SMF 28e® ULTRA 200)
General Specifications
Product Number | 036ZK4-13142A20 |
Cable type | Central Tube |
Environment | Outdoor |
Product type | Dielectric |
Fibre category | Single-mode (OS2) |
Application | Miniduct |
Cable geometry | Round |
Standards
Fibre Standards | TIA/EIA-492CAAB, IEC 60793-2-50 Type B1.3, ISO/IEC 11801 Ed.2.2 |
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Environmental Conditions
Temperature range, installation | -5 °C to 50 °C |
Temperature range, operation | -20 °C to 60 °C |
Temperature range, storage | -25 °C to 60 °C |
Cable Design
Cable marking | Meter Handset D-Sine CORNING Year MINIXTEND(R) A-D(ZN)2Y 36F E9U200 CT2.0 |
Fibre count | 36 |
Outer jacket colour | Black |
Outer jacket material | Polyethylene (PE) |
Buffer tube diameter | 2 mm |
Cable marking method | Laser printing |
Cable marking colour | White |
Fibres per tube | 36 |
Mechanical Specifications
Crush resistance | 500 N/10 cm |
Max. tensile strength, short-term | 80 N |
Min. bend radius installation | 90 mm |
Nominal outer diameter | 2.9 mm |
Optical Characteristics
Fibre code | Z |
Fibre name | SMF-28® Ultra 200 fibre |
Fibre Type | Single-mode |
Performance option code | 42 |
Cladding diameter | 125 µm |
Maximum Attenuation | 0.36 dB/km / 0.36 dB/km / 0.22 dB/km |
Mode-Field Diameter at 1310 nm | 9.2 µm |
Serial 1 gigabit ethernet | 5000 m / - |
Wavelengths | 1310 nm / 1383 nm / 1550 nm |
Coating diameter | 200 µm |
Dimensions
Cable Weight | 8 kg/km |
Max. cable length per reel/drum | 6000 m |
Improved cable and fibre density
Reduced cable diameter for installation in micro ducts with 4mm minimum inner diameter
Fully-dielectric
No grounding required
Optimised for air-assisted install in microducts
Capable of installation distances greater than 2000 m (6560 ft) at speeds up to 150 m/min (490 ft/min)
SMF-28e+®according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion