text.skipToContent text.skipToNavigation

004EK4-13122A20

MiniXtend® Cable, CT  A-D(ZN)2Y, 1x4 F, CT, Single-mode (SMF 28e+®)

通用规范
产品编码 004EK4-13122A20
EAN Code 4042673492788
Cable Type Single Tube
Environment Outdoor
Product Type Dielectric
Fiber Category Single-mode (OS2)
Application Miniduct 
Cable geometry Round
Standards
Fiber Standards TIA/EIA-492CAAB,  IEC 60793-2-50 Type B1.3,  ITU-T G.652.D,  ISO/IEC 11801 Ed.2.2 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Installation -5 °C  -  50 °C    (23 °F  -  122 °F    )
Temperature Range, Operation -20 °C  -  60 °C    (-4 °F  -  140 °F    )
Temperature Range, Storage -25 °C  -  60 °C    (-13 °F  -  140 °F    )
Cable Design
Cable Marking Meter Handset D-Sine CORNING Year MINIXTEND(R) A-D(ZN)2Y 4F E9 CT1.7
Fiber Count 4
Number of Ripcords 1
Outer Jacket Color Black
Outer Jacket Material Polyethylene (PE)
Buffer Tube Diameter 1.75 mm
Cable Marking Method Laser printing
Cable Marking Color White
Fiber Coloring Blue, Orange, Green, Brown
Fibers per Tube
Mechanical Specifications
Crush Resistance 1000 N/10 cm
Max. Tensile Strength, Short-Term 80 N
Min. Bend Radius Installation 20 mm
Nominal Outer Diameter 2.5 mm 
Optical Characteristics
Fiber Code E
Performance Option Code 22
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name Single-mode (OS2)
Maximum Attenuation 0.36 dB/km / 0.36 dB/km / 0.22 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Compliance ITU-T G.652.D
Fiber Core Diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm*km)]
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 9.2 µm
Mode-Field Diameter at 1550 nm 10.4 µm
PMD Link Design Value ≤ 0.06 ps/√km
PMD maximum individual fiber ≤ 0.1 ps/√km
Dimensions
Cable Weight 4.5 kg/km
Max. cable length per reel/drum 6000 m
Improved cable and fiber density
Reduced cable diameter for installation in micro ducts with 4mm minimum inner diameter
Fully dielectric
No grounding required
Optimized for air-assisted install in microducts
Capable of installation distances greater than 2000 m (6560 ft) at speeds up to 150 m/min (490 ft/min)
SMF-28e+®according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion