text.skipToContent text.skipToNavigation

072ZM4-T3122A20

MiniXtend® Cable, LT, A-DQ(ZN)2Y  6x12 F, Single-mode (E9 G.657.A1)

Contact Distributor for Lead Time

General Specifications
Product Number 072ZM4-T3122A20
Cable Type Stranded Loose Tube
Environment Outdoor
Product Type Dielectric
Fiber Category Single-mode (OS2)
Application Miniduct 
Standards
Fiber Standards TIA/EIA-492CAAB,  IEC 60793-2-50 Type B1.3,  ITU-T G.652.D,  ITU-G.657.A1,  ISO/IEC 11801 Ed.2.2 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Installation -5 °C  to  40 °C    (23 °F  to  104 °F    )
Temperature Range, Operation -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Temperature Range, Storage -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Cable Design
Cable Marking Meter - Handset - Sine - CORNING - Year -MINIXTEND (R) 6x12 E9G.657.A1 LT 1.4
Central Element Dielectric
Number of Ripcords 2
Buffer Tube Color Coding, Layer 1 Blue, Orange, Green, Brown, Slate, White
Outer Jacket Nominal Thickness 0.5 mm
Buffer Tube Diameter 1.4 mm
Number of Active Tubes 6
Number of Tube Positions 6
Tape Water-swellable
Cable Marking Method Laser printing
Cable Marking Color White
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Fibers per Tube 12 
Mechanical Specifications
Crush Resistance 1000 N/10 cm
Max. Tensile Strength, Short-Term 350 N
Min. Bend Radius Installation 106 mm
Min. Bend Radius Operation 80 mm
Nominal Outer Diameter 5.3 mm 
Optical Characteristics
Fiber Code Z
Performance Option Code 22
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name Bend-Improved Single-mode (OS2)
Maximum Attenuation 0.36 dB/km / 0.36 dB/km / 0.22 dB/km
Wellenlänge 1310 nm / 1383 nm / 1550 nm
Faserkonformität ITU-T G.652.D und ITU-T G.657.A1
Faserkerndurchmesser 8,2 µm
Mantelglasdurchmesser 125 µm
Coating-Durchmesser 242 µm
Dispersion bei 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion bei 1625 nm ≤ 22 [ps/(nm*km)]
Kabel-Grenzwellenlänge 1260 nm
Modenfelddurchmesser bei 1310 nm 9,2 µm
PMD (Polarisationsmodendispersion) Link Design Wert ≤ 0,04 ps/√km
Maximale Polarisationsmodendispersion (PMD) der einzelnen Faser ≤ 0,1 ps/√km
Ordering Information
Maximum Delivery Length 4000 m
Reduzierter Außenkabeldurchmesser
Installation in Mikrorohrsystemen für Metro, Access und FTTx Netzwerke
Kompaktes Design und reduziertes Gewicht
Reduzierte Investitionskosten
Optimierte Kabelsteifigkeit
Verbesserte Einblas- und Installationseigenschaften
Nicht metallischer Kabelaufbau
Keine Erdung erforderlich
Farbdocierte Adern und Fasern
Einfache Identifikation der einzelnen Adern
SMF-28e+® entsprechend ITU-T G.652.D
Sichere Übertragungseigenschaften und niedrige Dämpfung