![](https://test-portal.corning.com/cornservice/sessionRefresh.png)
![1 F, E9 Single-Mode ClearCurve™ R7.5 Bend Fibre (LBL)](https://www.corning.com/catalog/coc/products/s/sst-drop-single-tube-dielectric-gel-filled-cable/001JB4-13122A20/images/001JB4-13122A20_A.jpg/_jcr_content/renditions/product.zoom.1200.jpg)
001JB4-13122A20
SST-Drop™ Single-Tube, Dielectric, Gel-Filled Cable 1 F, E9 Single-Mode ClearCurve™ R7.5 Bend Fibre (LBL)
General Specifications
Product Number | 001JB4-13122A20 |
Cable Type | Single Tube |
Environment | Outdoor |
Product Type | Self-Supporting, Figure-8 |
Fiber Category | ClearCurve® LBL |
Application | Aerial, Duct, Drop |
Cable geometry | Other |
Standards
Reaction to Fire | Fca |
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Waterblocking | IEC 60794-1-22 Method F5B |
Level of corrosion | Non-corrosive according to IEC 60754-2 |
Environmental Conditions
Temperature Range, Installation | -30 °C to 70 °C (-22 °F to 158 °F ) |
Temperature Range, Operation | -40 °C to 70 °C (-40 °F to 158 °F ) |
Temperature Range, Storage | -40 °C to 70 °C (-40 °F to 158 °F ) |
Cable Design
Cable Marking | Metre - CORNING - Year (20xx) - 1E9/125 CLEARCURVE LBL R7,5 |
Central Element | Dielectric |
Fiber Count | 1 |
Outer Jacket Color | Black |
Outer Jacket Material | Polyethylene (PE) |
Buffer Tube Diameter | 3 mm |
Cable Marking Color | White |
Fiber Coloring | White |
Fibers per Tube | 1 |
Color Code Standards | Telcordia |
Mechanical Specifications
Crush Resistance | 3000 N/10 cm |
Max. Tensile Strength, Long-Term | 400 N |
Max. Tensile Strength, Short-Term | 1350 N |
Min. Bend Radius Operation | 80 mm |
Nominal Outer Diameter | 8.1 mm x 4.5 mm |
Optical Characteristics
Fiber Name | ClearCurve® LBL |
Fiber Type | Single-mode |
Cladding diameter | 125 µm ± 0.7µm |
Maximum Attenuation | 0.36 dB/km / 0.22 dB/km |
Fiber Bend Performance at 1550nm 7.5mm radius | ≤ 0.2 dB/turn |
Mode-Field Diameter at 1310 nm | 8.6 µm |
Mode-Field Diameter at 1550 nm | 9.65 µm |
Wavelengths | 1310 nm / 1550 nm |
PMD Link Design Value | ≤ 0.06 ps/(nm*km) |
PMD maximum individual fiber | ≤ 0.2 ps/(nm*km) |
Fiber Category | SM Bend Resistant (G657.A2/B2) |
Dimensions
Cable Weight | 30 kg/km |
Dielectric design
Eliminates bonding
Standard ALTOS® Cable tube design in single-tube design
Standard practices and hardware compatibility
Crush resistance
Fiber protection and signal integrity