text.skipToContent text.skipToNavigation

012EB4-13122A20

SST-Drop™ Single-Tube, Dielectric, Gel-Filled Cable  12 F, single-mode (OS2)

Contact Distributor for Lead Time

General Specifications
Product Number 012EB4-13122A20
Cable Type Single Tube
Environment Outdoor
Product Type Self-Supporting, Figure-8
Fiber Category Single-mode (OS2)
Application Aerial,  Duct,  Drop 
Cable geometry Other
Standards
Reaction to Fire Fca
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Waterblocking IEC 60794-1-22 Method F5B
Level of corrosion Non-corrosive according to IEC 60754-2
Environmental Conditions
Temperature Range, Installation -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Temperature Range, Operation -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Temperature Range, Storage -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Cable Design
Cable Marking Metre - CORNING -Month/Year - Handset - 12 SME - ID Number
Central Element Dielectric
Fiber Count 12
Outer Jacket Color Black
Outer Jacket Material Polyethylene (PE)
Buffer Tube Diameter 3 mm
Cable Marking Color White
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Fibers per Tube 12 
Color Code Standards Telcordia
Mechanical Specifications
Crush Resistance 3000 N/10 cm
Max. Tensile Strength, Long-Term 400 N
Max. Tensile Strength, Short-Term 1350 N
Min. Bend Radius Operation 80 mm
Nominal Outer Diameter 8.1 mmx  4.5 mm 
Optical Characteristics
Fiber Code E
Performance Option Code 22
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name Single-mode (OS2)
Maximum Attenuation 0.36 dB/km / 0.36 dB/km / 0.22 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Compliance ITU-T G.652.D
Fiber Core Diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm*km)]
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 9.2 µm
Mode-Field Diameter at 1550 nm 10.4 µm
PMD Link Design Value ≤ 0.06 ps/√km
PMD maximum individual fiber ≤ 0.1 ps/√km
Dimensions
Cable Weight 30 kg/km
Dielectric design
Eliminates bonding
Standard ALTOS® Cable tube design in single-tube design
Standard practices and hardware compatibility
Crush resistance
Fiber protection and signal integrity