text.skipToContent text.skipToNavigation

016ZB4-13120A20

SST-Drop™ Single-Tube, Dielectric, Gel-Filled Cable  16 F, E9/125 SMF-28® ULTRA

Contact Distributor for Lead Time

General Specifications
Product Number 016ZB4-13120A20
Cable Type Single Tube
Environment Outdoor
Product Type Self-Supporting, Figure-8
Fiber Category SMF-28® Ultra
Application Aerial,  Duct,  Drop 
Cable geometry Other
Standards
Reaction to Fire Fca
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Waterblocking IEC 60794-1-22 Method F5B
Level of corrosion Non-corrosive according to IEC 60754-2
Environmental Conditions
Temperature Range, Installation -5 °C  to  70 °C    (23 °F  to  158 °F    )
Temperature Range, Operation -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Temperature Range, Storage -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Cable Design
Cable Marking Metre - CORNING -Month/Year - Handset - 16E9ULTRA - ID Number
Central Element Dielectric
Fiber Count 16
Outer Jacket Color Black
Outer Jacket Material Polyethylene (PE)
Buffer Tube Diameter 3 mm
Cable Marking Color White
Fiber Coloring 1-12: blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, aqua - 13-24 (all with one black ring mark) blue, orange, green, brown, slate, white, red, natural, yellow, violet, rose, aqua
Fibers per Tube 16 
Color Code Standards Telcordia
Mechanical Specifications
Crush Resistance 3000 N/10 cm
Max. Tensile Strength, Long-Term 400 N
Max. Tensile Strength, Short-Term 1350 N
Min. Bend Radius Operation 80 mm
Nominal Outer Diameter 8.1 mm x  4.5 mm 
Optical Characteristics
Cable cutoff wavelength 1260 nm
Fiber Code Z
Fiber Name SMF-28® Ultra
Fiber Type Single-mode
Fiber Compliance ITU-T G.652.D and ITU-T G.657.A1
Fiber Core Diameter 8.2 µm
Cladding diameter 125 µm
Maximum Attenuation 0.34 dB/km / 0.34 dB/km / 0.20 dB/km
Mode-Field Diameter at 1310 nm 9.2 µm
Typical Attenuation 0.32 dB/km / 0.32 dB/km / 0.18 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
PMD Link Design Value ≤ 0.04 ps/(nm*km)
PMD maximum individual fiber ≤ 0.1 ps/(nm*km)
Coating diameter 242 µm
Fiber Category OS2 
Dimensions
Cable Weight 30 kg/km
Dielectric design
Eliminates bonding
Standard ALTOS® Cable tube design in single-tube design
Standard practices and hardware compatibility
Crush resistance
Fiber protection and signal integrity