text.skipToContent text.skipToNavigation

060ZM4-T3120A20

MiniXtend® Cable, LT, A-DQ(ZN)2Y  5x12 E9/125 SMF-28® Ultra

Contact Distributor for Lead Time

General Specifications
Product Number 060ZM4-T3120A20
Cable Type Stranded Loose Tube
Environment Outdoor
Product Type Dielectric
Fiber Category Single-mode (OS2)
Application Miniduct 
Standards
Fiber Standards TIA/EIA-492CAAB,  IEC 60793-2-50 Type B1.3,  SMF-28® Ultra fiber ITU-TG.652.D + ITU-TG.657.A1,  ISO/IEC 11801 Ed.2.2 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Installation -5 °C  to  40 °C    (23 °F  to  104 °F    )
Temperature Range, Operation -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Temperature Range, Storage -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Cable Design
Cable Marking Meter - Handset - Sine - CORNING - Year -MINIXTEND (R) 5X12 E9U LT 1.4
Central Element Dielectric
Number of Ripcords 2
Outer Jacket Nominal Thickness 0.5 mm
Buffer Tube Diameter 1.4 mm
Number of Active Tubes 5
Number of Filling Elements 1
Number of Tube Positions 6
Tape Water-swellable
Cable Marking Method Laser printing
Cable Marking Color White
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Fibers per Tube 12 
Mechanical Specifications
Crush Resistance 1000 N/10 cm
Max. Tensile Strength, Short-Term 350 N
Min. Bend Radius Installation 106 mm
Min. Bend Radius Operation 79.5 mm
Nominal Outer Diameter 5.3 mm 
Optical Characteristics
Fiber Code Z
Performance Option Code 20
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name Bend-Improved Single-mode (OS2)
Maximum Attenuation 0.34 dB/km / 0.34 dB/km / 0.20 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Compliance ITU-T G.652.D and ITU-T G.657.A1
Fiber Core Diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm*km)]
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 9.2 µm
Mode-Field Diameter at 1550 nm 10.4 µm
PMD Link Design Value ≤ 0.04 ps/√km
PMD maximum individual fiber ≤ 0.1 ps/√km
Ordering Information
Maximum Delivery Length 4000 m
Reduced outer cable diameter
High fiber density in microduct systems
Compact and light
CapEx-optimized installations and upgrades
Optimized cable stiffness
Long installation lengths
Fully dielectric
No grounding required
Color-coded tubes and fibers
Easy identification of tubes and 
SMF-28e+® according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion