text.skipToContent text.skipToNavigation

144ZM4-T3120A20

MiniXtend® Cable, LT, A-DQ(ZN)2Y  12x12 E9/125 SMF-28® Ultra

Contact Distributor for Lead Time

General Specifications
Product Number 144ZM4-T3120A20
EAN Code 4056418062914
Cable type Stranded Loose Tube
Environment Outdoor
Product type Dielectric
Fibre category SMF-28® Ultra
Application Miniduct 
Cable geometry Round
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature range, installation -5 °C  to  40 °C   
Temperature range, operation -30 °C  to  70 °C   
Temperature range, storage -30 °C  to  70 °C   
Cable Design
Cable marking Metre - Handset - Sine - CORNING - Year -MINIXTEND (R) CABLE 12X12 E9/125 ULTRA LT 1.4
Central element Dielectric
Fibre count 144
Number of ripcords 2
Outer jacket colour Black
Outer jacket material High Density Polyethylene (HDPE)
Outer jacket nominal thickness 0.5 mm
Buffer tube diameter 1.4 mm
Number of active tubes 12
Number of tube positions 12
Tape Water-swellable
Fibre colouring Blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, turquoise
Fibres per tube 12 
Mechanical Specifications
Crush resistance 1000 N/10 cm
Max. tensile strength, short-term 1000 N
Min. bend radius installation 160 mm
Min. bend radius operation 120 mm
Nominal outer diameter 8 mm 
Optical Characteristics
Fibre code Z
Performance option code 20
Fibre category OS2 
Fibre Type Single-mode (OS2) / 250 µm
Fibre name Bend-Improved Single-mode (OS2)
Maximum Attenuation 0.34 dB/km / 0.34 dB/km / 0.20 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fibre compliance ITU-T G.652.D and ITU-T G.657.A1
Fibre core diameter 8.2 µm
Cladding diameter 125 µm
Coating diameter 242 µm
Dispersion @ 1550 nm ≤ 18 [ps/(nm*km)]
Dispersion @ 1625 nm ≤ 22 [ps/(nm*km)]
Cable cutoff wavelength 1260 nm
Mode-Field Diameter at 1310 nm 9.2 µm
Mode-Field Diameter at 1550 nm 10.4 µm
PMD Link Design Value ≤ 0.04 ps/√km
PMD (Polarization Mode Dispersion) maximum individual fibre ≤ 0.1 ps/√km
Dimensions
Cable Weight 55 kg/km
Max. cable length per reel/drum 4000 m
Reduced outer cable diameter
High fibre density in microduct systems
Compact and light
CapEx-optimised installations & upgrades
Optimised cable stiffness
Long installation lengths
Fully-dielectric
No grounding required
Colour-coded tubes & fibres
Easy identification of tubes & fibres
SMF-28e+® according to ITU-T G.652.D
Transmission security, low attenuation and polarization mode dispersion