text.skipToContent text.skipToNavigation

288ZZZ-14161B20

MiniXtend® Indoor/Outdoor Ribbon Cable-200 Flow  288F, Bend-Improved Single-mode (OS2)

Typically ships in 42 day(s) Actual lead time confirmed upon receipt of order.

General Specifications
Product Number 288ZZZ-14161B20
EAN Code 4099802348768
Environment Indoor/Outdoor
Fiber Category G.657.A1 190
Flame Rating Riser/LSZH (OFNR-LS)
Application Miniduct 
Cable geometry Round
Standards
Reaction to Fire Cca, s1, d1, a1
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Approvals and Listings National Electrical Code® (NEC®) OFNR-LS, CSA FT-4 and UKCA 
Design and Test Criteria ANSI/ICEA S-104-696 
Flame Test Method UL-1666 (for riser and general building applications),  UL-1685 (National Electrical Code® (NEC®) OFN-LS) 
Reaction to Fire Requirements Reaction to fire according to EN 50575 and EN 13501-6
Environmental Conditions
Temperature Range, Installation -10 °C  to  60 °C    (14 °F  to  140 °F    )
Temperature Range, Operation -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Temperature Range, Storage -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Cable Design
Fiber Count 288
Outer Jacket Color Black
Outer Jacket Material Polyethylene (FRNC/LSZH)
Tape Water-swellable
Mechanical Specifications
Max. Tensile Strength, Long-Term 400 N (89.92 lbf)
Max. Tensile Strength, Short-Term 1330 N (299 lbf)
Nominal Outer Diameter 9.1 mm  (0.36 in )
Min. Bend Diameter Operation 274 mm (10.79 in)
Min. Bend Diameter Installation 364 mm (14.33 in)
Optical Characteristics
Fiber Code Z
Fiber Name G.657.A1 Optical fiber with 190-micron outer diameter
Fiber Type Single-mode
Fiber Compliance ITU-T G.652.D and ITU-T G.657.A1
Performance Option Code 61
Cladding diameter 125 µm
Maximum Attenuation 0.4 dB/km / 0.4 dB/km / 0.3 dB/km
Mode-Field Diameter at 1310 nm 9.2 µm
Wavelengths 1310 nm / 1550 nm
PMD maximum individual fiber ≤ 0.1 ps/(nm*km)
Coating diameter 188 µm
Fiber Category G.652.D/G.657.A1 
Dimensions
Cable Weight 88 kg/km (59.13 lb/1000 ft)
Bend-Improved Single-mode 190 μm Diameter
ITU-T G.652.D and G.657.A1-compliant 190 micron single-mode fiber with a 9.2 μm MFD maintains full compatibility with existing fiber networks
Flow Ribbon Technology
Allows for smaller cable designs and easier routing in hardware. Flow Ribbons are compatible with both 200 μm and 250 μm commercially available splicers

Reduced Cable Diameter

High fiber density in microduct systems. Up to 57% reduction in cable diameter (compared to existing SST-UltraRibbon™) doubling fiber count per duct at similar ODs

Optimized for air-assisted install in microducts

Capable of long installation distances

Indoor/Outdoor Jacket

Eliminates the need for a transitionsplice at building entry.

Dual Flame Rated

Allows cable to be used anywhere around the globe