text.skipToContent text.skipToNavigation

G909024GPNDDU060F

EDGE™ MTP® Trunk  Bend-improved Single-mode (OS2), MTP® Connector to MTP Connector, 24 F, with 33/33 inch legs, pulling grip one side, 60 ft

Typically ships in 10 day(s) Actual lead time confirmed upon receipt of order.
You might also be interested in
General Specifications
Product Number G909024GPNDDU060F
Flame Rating Plenum (OFNP)
Fiber Category Bend-improved SM (OS2)
Cable Assembly Type EDGE™ Trunk
Environment Indoor
Application Data Center 
Pulling grip Yes
Connector Assembly Type MTP to MTP
Standards
Fiber Standards ITU-T G.652.D and ITU-T G.657.A1 
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Approvals and Listings NFPA 262, National Electrical Code® (NEC®), OFNP, CSA FT-6 
Design and Test Criteria ANSI/ICEA S-83-596 
Environmental Conditions
Temperature Range, Installation -10 °C  to  60 °C    (14 °F  to  140 °F    )
Temperature Range, Operation -10 °C  to  60 °C    (14 °F  to  140 °F    )
Design
Fiber Count 24
Polarity Universal, TIA-568 Type-B
Strain-Relief Bracket Type 1
Fiber Type Single-Mode Ultra-Bendable Fiber
Mechanical Specifications
Nominal Outer Diameter 7.7 mm    ± 0.3mm (0.3 in    ± 0.01in)
Max. Tensile Strength for Installation 660 N (148.37 lbf)
Min. Bend Radius Installation 115.5 mm (4.55 in)
Min. Bend Radius Operation 38.5 mm (1.52 in)
Minimum Conduit Size with 18-in Elbow 63.5 mm (2.5 in)
Optical Characteristics
Fiber Code Z
Performance Option Code 01
Fiber Category OS2 
Fiber Type Single-mode (OS2) / 250 µm
Fiber Name Bend-Improved Single-mode (OS2)
Maximum Attenuation 0.4 dB/km / 0.4 dB/km / 0.3 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Compliance ITU-T G.652.D and ITU-T G.657.A1
Specifications - Connector A
Insertion Loss, Max. 0.75 dB
Connector Type MTP® (non-pinned)
Ferrule Material Composite
Reflectance < -55 dB
Specifications - Connector B
Insertion Loss, Max. 0.75 dB
Connector Type MTP® (non-pinned)
Ferrule Material Composite
Reflectance < -55 dB
Pulling Grip - Connector A
Pulling grip Yes
Tensile Strength 440 N (98.92 lbf)
Grip Outer Diameter 41 mm (1.61 in)
Pulling Grip - Connector B
Min. Duct Size Diameter 64 mm (2.52 in)
Dimensions
Length 60 ft   -0 / +0.61m
Cable Weight 50 kg/km (33.6 lb/1000 ft)
Ordering Information
Reel Diameter 23.5 in
Reel Width 5 in
Units per Delivery 1/1
Furcation - Connector A
Leg Length 838 mm   -0 / +76mm (32.99 in   -0 / +2.99in)
Furcation Type EDGE™ Size 1, 14.7 mm x 14.7 mm x 108.6 mm
Leg Color Yellow
Leg Diameter 2 mm (0.08 in)
Furcation - Connector B
Furcation Type EDGE™ Size 1, 14.7 mm x 14.7 mm x 108.6 mm
Leg Diameter 2 mm (0.08 in)
Leg Length 838 mm (32.99 in)
Clipes de alívio de tensão de fácil instalação
Gestão de cabeamento mais simples
Diâmetro externo reduzido
Melhora a taxa de preenchimento da bandeja de cabos e permite um fluxo de ar aprimorado
Conectividade com baixa perda
Maior flexibilidade no projeto do sistema
Fibra mais resistente a curvaturas
Permite curvaturas mais fechadas no roteamento e no armazenamento de folga do cabo; menor risco de inatividade devido a cabos comprimidos ou dobrados
Tecnologia CleanAdvantage ™ da Corning® e tampa contra poeira otimizada
Elimina a necessidade de delimitação e limpeza antes da primeira conexão em campo
Conectores MTP® sem pinos nas duas pontas
Trunks de fibra óptica projetados para conexão com as soluções EDGE ou módulos de sistemas Plug & Play™