432ZH4-S4F40A20
MiniXtend® HD Cable with Binderless* FastAccess® Technology 432 F (36F/Tube), SMF-28® Ultra fiber, Single-mode (G.652.D/G.657.A1)
General Specifications
Product Number | 432ZH4-S4F40A20 |
Cable Type | Stranded Loose Tube |
Environment | Outdoor |
Product Type | Dielectric |
Fiber Category | SMF-28® Ultra 200 Optical Fiber |
Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) | A-DQ(ZN)2Y |
Application | Miniduct |
Cable geometry | Round |
Standards
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Environmental Conditions
Temperature Range, Installation | -15 °C to 60 °C (5 °F to 140 °F ) |
Temperature Range, Operation | -40 °C to 70 °C (-40 °F to 158 °F ) |
Temperature Range, Storage | -40 °C to 70 °C (-40 °F to 158 °F ) |
Cable Design
Cable Marking | FT#CORNING OPTICAL CABLE#MM-YY# 432 (12x36) SM- ULTRA 200 MINIXTEND(R) HD CABLE WITH BINDERLESS FASTACCESS(R) TECHNOLOGY |
Central Element | Dielectric |
Fiber Count | 432 |
Buffer Tube Color Coding, Layer 1 | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua |
Outer Jacket Color | Black |
Outer Jacket Material | Polyethylene (PE) |
Outer Jacket Nominal Thickness | 0.5 mm (0.02 in) |
Buffer Tube Diameter | 1.95 mm (0.08 in) |
Number of Active Tubes | 12 |
Number of Tube Positions | 12 |
Fiber Coloring | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua |
Fibers per Tube | 36 |
Color Code Standards | Telcordia |
Mechanical Specifications
Crush Resistance | 1000 N/10 cm |
Max. Tensile Strength, Short-Term | 1334 N (299.9 lbf) |
Min. Bend Radius Installation | 220 mm (8.66 in) |
Min. Bend Radius Operation | 165 mm (6.5 in) |
Nominal Outer Diameter | 10.8 mm (0.43 in ) |
Min. Duct Size Diameter | 14 mm (0.55 in) |
Optimal Duct Size | 16 mm (0.63 in) |
Optical Characteristics
Cable cutoff wavelength | 1260 nm |
Fiber Code | Z |
Fiber Name | SMF-28® Ultra 200 fiber |
Fiber Type | Single-mode |
Performance Option Code | 40 |
Cladding diameter | 125 µm ± 0.7µm |
Maximum Attenuation | 0.34 dB/km / 0.34 dB/km / 0.20 dB/km |
Fiber Bend Performance at 1550nm 7.5mm radius | ≤ 0.4 dB/turn |
Mode-Field Diameter at 1310 nm | 8.6 µm ± 0.4µm |
Mode-Field Diameter at 1550 nm | 9.6 µm ± 0.5µm |
Typical Attenuation | 0.32 dB/km / 0.32 dB/km / 0.18 dB/km |
Wavelengths | 1310 nm / 1383 nm / 1550 nm |
PMD Link Design Value | ≤ 0.06 ps/(nm*km) |
PMD maximum individual fiber | ≤ 0.2 ps/(nm*km) |
Fiber Category | G.652.D/G.657.A1 |
Dispersion @ 1550 nm | ≤ 18 [ps/(nm ⋅ km)] |
Dimensions
Cable Weight | 110 kg/km (73.92 lb/1000 ft) |
Max. cable length per reel/drum | 6000 m (19680 ft) |
Length | 0 mm (0 in) |
Binderless FastAccess™ Technology
Innovative cable design that reduces cable access time up to 70 percent and lowers the risk of inadvertent fibre damage
Reduced outer cable diameter
High fiber density in microduct systems
Compact and light
CapEx-optimized installations and upgrades
Fully dielectric
No grounding required
Color-coded tubes and fibers
Easy identification of tubes and