text.skipToContent text.skipToNavigation

216ZH4-Y4C49A20

MiniXtend® XD Cable with Binderless* FastAccess™ Technology, A-DQ(ZN)2Y  216 F (9x24), G.657.A1 190

Contact Distributor for Lead Time

General Specifications
Product Number 216ZH4-Y4C49A20
Cable Type Stranded Loose Tube
Product Type Dielectric
Fiber Category G.657.A1 190
Application Miniduct 
Cable geometry Round
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Installation -5 °C  to  50 °C    (23 °F  to  122 °F    )
Temperature Range, Operation -20 °C  to  70 °C    (-4 °F  to  158 °F    )
Temperature Range, Storage -30 °C  to  70 °C    (-22 °F  to  158 °F    )
Cable Design
Cable Marking Meter - Handset - Sine - CORNING - Year -MINIXTEND (R) XD FAB CABLE 9X24 G.657.A1 190
Central Element Dielectric
Fiber Count 216
Outer Jacket Color Black
Outer Jacket Material High Density Polyethylene (HDPE)
Outer Jacket Nominal Thickness 0.4 mm (0.02 in)
Buffer Tube Color Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow
Buffer Tube Diameter 1.4 mm (0.06 in)
Fiber Bundle Coloring 1-12: blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, aqua - 13-24 (all with one black ring mark) blue, orange, green, brown, slate, white, red, natural, yellow, violet, rose, aqua
Number of Active Tubes 9
Number of Tube Positions 9
Fiber Coloring 1-12: blue, orange, green, brown, slate, white, red, black, yellow, violet, rose, aqua - 13-24 (all with one black ring mark) blue, orange, green, brown, slate, white, red, natural, yellow, violet, rose, aqua
Color Code Standards Telcordia
Mechanical Specifications
Crush Resistance 500 N/10 cm
Max. Tensile Strength, Short-Term 1000 N (224.81 lbf)
Nominal Outer Diameter 7 mm  (0.28 in )
Min. Bend Diameter Installation 280 mm (11.02 in)
Min. Bend Diameter Operation 210 mm (8.27 in)
Optical Characteristics
Cable cutoff wavelength 1260 nm
Fiber Code Z
Fiber Name G.657.A1 Optical fiber with 190-micron outer diameter
Fiber Type Single-mode
Fiber Compliance ITU-T G.652.D and ITU-T G.657.A1
Performance Option Code 49
Cladding diameter 125 µm
Maximum Attenuation 0.36 dB/km / 0.22 dB/km
Mode-Field Diameter at 1310 nm 9.2 µm
Wavelengths 1310 nm / 1550 nm
PMD maximum individual fiber ≤ 0.1 ps/(nm*km)
Coating diameter 188 µm
Fiber Category G.652.D/G.657.A1 
Dimensions
Cable Weight 48 kg/km (32.25 lb/1000 ft)
Binderless FastAccess™ Technology
Innovative cable design that reduces cable access time up to 70 percent and lowers the risk of inadvertent fibre damage
Improved cable and fiber density
Small cable OD enables higher density and lower deployment cost
Optimized for air-assisted install in microducts

Suitable for installation in a duct with 10-mm inner diameter