text.skipToContent text.skipToNavigation

024TCJ-14131-20

LSZH Ribbon Cable  24 F, 50 µm multimode (OM2)

Typically ships in 14 day(s) Actual lead time confirmed upon receipt of order.

General Specifications
Product Number 024TCJ-14131-20
Cable Type Ribbon
Environment Indoor
Product Type Distribution
Fiber Category 50 µm MM (OM2)
Flame Rating LSZH (OFNR-LS)
Application Vertical Riser,  General purpose,  Horizontal 
Cable geometry Round
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Approvals and Listings National Electrical Code® (NEC®) OFNR-LS, IEEE 383 
Design and Test Criteria ANSI/ICEA S-83-596; UL-1685; UL 1666; CSA FT-4
Environmental Conditions
Temperature Range, Installation -30 °C  to  60 °C    (-22 °F  to  140 °F    )
Temperature Range, Operation -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Temperature Range, Storage -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Cable Design
Buffer Tube Color Natural
Fiber Count 24
Buffer Tube Diameter 58 mm (2.28 in)
Number of Ripcords 2
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Outer Jacket Color Orange
Outer Jacket Material Flame-retardant
Tensile Strength Elements and/or Armoring - Layer 1 Dielectric strength members
Tape Water-swellable
Ribbons per Tube
Fibers per Ribbon 12 
Mechanical Specifications
Max. Tensile Strength, Long-Term 400 N (89.92 lbf)
Max. Tensile Strength, Short-Term 400 N (89.92 lbf)
Min. Bend Radius Installation 146 mm (5.75 in)
Min. Bend Radius Operation 97 mm (3.82 in)
Nominal Outer Diameter 9.7 mm  (0.38 in )
Optical Characteristics
Fiber Code T
Fiber Type Multimode
Performance Option Code 31
Fiber Core Diameter 50 µm
Minimum Effective Modal Bandwidth (EMB) 950 MHz*km / -
Maximum Attenuation 3.0 dB/km / 1.0 dB/km
Min. Overfilled Launch (OFL) Bandwidth 700 MHz*km / 500 MHz*km
Serial 1 Gigabit Ethernet 750 MHz*km / 500 MHz*km
Serial 10 Gigabit Ethernet 150 MHz*km / -
Wavelengths 850 nm / 1300 nm
Fiber Category OM2 
Dimensions
Length 0 mm (0 in)
Cable Weight 94.8 kg/km (63.7 lb/1000 ft)
Precise fiber and ribbon geometries
Excellent mass splicing yields
Ribbon ID numbers and fiber colors
Easily identifiable
Available with interlocking armor
Additional mechanical durability
Common installations
Indoor vertical riser and general purpose horizontal according to National Electrical Code (NEC) Article 770