text.skipToContent text.skipToNavigation

IA340532265

STG 2000  C2 10 marked 1 to 0

Typically ships in 28 day(s) Actual lead time confirmed upon receipt of order.

You might also be interested in
General Specifications
Product Number IA340532265
Product Type Disconnection Module
Legacy Part Number C252818A
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Environmental Conditions
Temperature Range, Operation -40 °C  to  70 °C    (-40 °F  to  158 °F    )
Temperature Range, Storage -40 °C  to  90 °C    (-40 °F  to  194 °F    )
Design
Number of Pairs 10
Mechanical Specifications
Contact material Bronze, tin (Sn) plating
Wire re-terminations 250 re-terminations of 24 AWG per Telcordia TR-NWT-001195
Wire range IDC contacts  - solid copper conductor 0.4 mm to 0.8 mm / 26 AWG to 20 AWG / T-connection/double jumpering possible with different wire gauges
Electrical Characteristics
Contact resistance Rd 10 mΩ
Dielectric Strength 3000 Vrms 60 Hz AC
High Voltage Surge 3000 VDC
Telcordia TR-NWT-001195 — Third party tested Yes
Transmission
Near end crosstalk > 73 dB to 2.2 MHz,> 60 dB to 12 MHz,> 53 dB to 30 MHz
Insertion loss (maximum) < 0.1 dB to 2.2 MHz,< 0.2 dB to 12 MHz,< 0.4 dB to 30 MHz
Return Loss > 50 dB to 2.2 MHz,> 38 dB to 12 MHz,> 30 dB to 30 MHz
Innovative design—quiet front/embedded IDC contacts in plastic casing
Non-protruding contacts offer good protection and a long life cycle. May prevent accidental contact or disconnection.
Very compact mounting pitch of 0.63 in/16 mm, vertical space between block rows
Can be used in applications where density is required (overcrowded MDFs, confined spaces of remote terminals or telecom closets in MDUs)
Cable with single wire conductors from 26 AWG (0.4 mm) to 20 AWG (0.8 mm) on cable and jumper sides. Multiple re-terminations (as per Telecordia NWT 1195) T-connection possible with two wires in one slot
Corning’s straight IDC technology offers outstanding mechanical, electrical, and environmental connection performances.
Versatile mounting
Mounting on a metallic back-mount frame to affix on a wall, in an equipment rack or in enclosures
Integrated front-mount forward surge protections
Enables front-facing frame overvoltage and overcurrent protection to equipment and staff while preserving density